RMHDC series
Low frequency inverter with mpptPure copper transformer
Triple peak value
OEM/ODM
Description
Power frequency inverter control integrated machine, built-in MPPT controller, 3 times the maximum peak power, optional single-phase 120V or 220V output, can choose split-phase 120V and 220V output. Ideal for home use on two circuits for power tools, computers, audio/video components, and other sensitive electronic equipment. This inverter has a hard shell and is not limited to home, commercial, industrial, marine and other scenarios.

MPPT Solar Charger (Optional)
Optional solar charger with MPPT functionality, rated output current up to 60A.
Pure Sine Wave Output
Provides pure sine wave output, same as input in bypass mode.


Multiple Input Voltages
Supports nominal input voltages of 12.0Vdc, 24.0Vdc, and 48.0Vdc.
Efficient Operation
Nominal efficiency greater than 88% and line mode efficiency >95%.

Electrical Specifications | ||||||||||||
Model | 1KW | 1.5KW | 2KW | 3KW | 4KW | 5KW | 6KW | 8KW | 10KW | 12KW | ||
Inverter Output | Continuous Output | 1KW | 1.5KW | 2KW | 3KW | 4KW | 5KW | 6KW | 8KW | 10KW | 12KW | |
Power | ||||||||||||
Surge Rating(20ms) | 3KW | 4.5KW | 6KW | 9KW | 12KW | 15KW | 18KW | 24KW | 30KW | 36KW | ||
Output Waveform | Pure Sine wave/Same as input(Bypass Mode) | |||||||||||
Nominal Efficiency | >88%(Peak) | |||||||||||
Line Mode Efficiency | >95% | |||||||||||
Power Factor | 0.9- 1.0 | |||||||||||
Nominal Output Voltage rms | 100- 110- 120Vac / 220-230-240Vac | |||||||||||
Output Voltage | ± 10% RMS | |||||||||||
Regulation | ||||||||||||
Output Frequency | 50Hz ± 0.3Hz/60Hz ± 0.3Hz | |||||||||||
Short Circuit Protection | Yes( 1sec after fault ) | |||||||||||
Typical transfer Time | 10ms(Max) | |||||||||||
THD | < 10% | |||||||||||
DC Input | Nominal Input Voltage | 12.0Vdc / 24.0Vdc / 48.0Vdc | 24.0Vdc /48.0Vdc | 48.0Vdc | ||||||||
Minimum Start Voltage | 10.0Vdc / 10.5Vdc for 12Vdc Mode | *2 for 24Vdc, *4 for 48Vdc; | ||||||||||
Low Battery Alarm | 10.5Vdc / 11.0Vdc for 12Vdc Mode | |||||||||||
Low Battery Trip | 10.0Vdc / 10.5Vdc for 12Vdc Mode | |||||||||||
High Voltage Alarm | 16.0Vdc for 12Vdc Mode | |||||||||||
Low Battery voltage recover | 15.5Vdc for 12Vdc Mode | |||||||||||
Idle Consumption-Search Mode | < 25 W when Power Saver On.(Refer to Table ) | |||||||||||
Charger | Output Voltage | Depends on battery type (Refer to Table 2.5.2) | ||||||||||
Charger Breaker Rating | 10A | 15A | 20A | 20A | 20A | 30A | 30A | 40A | 40A | 40A | ||
Max Charge Power | 1/3 Rating Power (Refer to Table 2.5.3) | |||||||||||
Rate | ||||||||||||
Battery Initial Voltage for Start | 10- 15.7Vdc for 12Vdc Mode | *2 for 24Vdc, *4 for 48Vdc; | ||||||||||
Over Charge Protection S.D. | 15.7Vdc for 12Vdc Mode | |||||||||||
BTS | Battery Temperature Sensor (Optional) | Yes(Refer to the table ) Variances in Charging Voltage & S.D Voltage Base on the Battery Temperature. | ||||||||||
Bypass & Protection | Input Voltage Waveform | Sine wave (Grid or Generator) | ||||||||||
Nominal Voltage | 110Vac | 120Vac | 220Va c | 230Va c | 230Vac | |||||||
Max Input AC Voltage | 150VAC For 120Vac LV Mode;300VAC For 230Vac HV Mode; | |||||||||||
Nominal Input Frequency | 50Hz or 60Hz | |||||||||||
Low Freq Trip | 47±0.3Hz for 50Hz, 57±0.3Hz for 60Hz | |||||||||||
High Freq Trip | 55±0.3Hz for 50Hz, 65±0.3Hz for 60Hz | |||||||||||
Overload protection (SMPS load) | Circuit Breaker | |||||||||||
Output Short circuit protection | Circuit Breaker | |||||||||||
Bypass breaker rating | 10A | 15A | 20A | 30A | 40A | 40A | 50A | 60A | 63A | 80A | ||
Transfer switch rating | 30Amp for UL & TUV | 40Amp for UL | 80Amp for UL | |||||||||
Bypass without battery connected | Yes (Optional) | |||||||||||
Max bypass current | 30Amp | 50Amp | 80Amp | |||||||||
Solar Charger (Optional) | Rated Voltage | 12Vdc / 24Vdc / 48Vdc | ||||||||||
Solar Input Voltage Range | 18- 150Vdc / 36- 150Vdc / 60- 150Vdc | |||||||||||
Rated Charge Current | 40 ~ 60A | |||||||||||
Rated Output Current | 60A | |||||||||||
Self Consumption | < 10mA | |||||||||||
Bulk Charge(Default) | 14.5Vdc for 12Vdc Mode | ( *2 for 24Vdc, *4 for 48Vdc) | ||||||||||
Floating Charge(Default) | 13.5Vdc for 12Vdc Mode | |||||||||||
Equalization Charge(Default) | 14.0Vdc for 12Vdc Mode | |||||||||||
Over Charge Disconnection | 14.8Vdc for 12Vdc Mode | |||||||||||
Over Charge Recovery | 13.6Vdc for 12Vdc Mode | |||||||||||
Over Discharge Disconnection | 10.8Vdc for 12Vdc Mode | |||||||||||
Over Discharge Reconnection | 12.3Vdc for 12Vdc Mode | |||||||||||
Temperature Compensation | 5mV/C/2V | |||||||||||
Ambient Temperature | -25C~60C | |||||||||||
Mechanical Specifications | Mounting | Wall Mount | ||||||||||
Inverter Dimensions(L*W*H) | 340*420*200mm | 420*420*200mm | 558*415*200mm | 618*430*238mm | ||||||||
Inverter Weight(Solar Chg)KG | 16+3 | 29+3 | 22+3 | 26+3 | 31+3 | 35+3 | 37+3 | 60+3 | 64+3 | 74+3 | ||
Shipping Weight(Solar Chg)KG | 19+3 | 22+3 | 25+3 | 29+3 | 36+3 | 39+3 | 41+3 | 70+3 | 74+3 | 84+3 | ||
Display | Status LEDs / Status LEDs+LCD | |||||||||||
Standard Warranty | 2 Years (Optional) |