Pure copper transformer
Triple peak value
OEM/ODM
Description
Power frequency inverter control integrated machine, built-in MPPT controller, 3 times the maximum peak power, optional single-phase 120V or 220V output, can choose split-phase 120V and 220V output. Ideal for home use on two circuits for power tools, computers, audio/video components, and other sensitive electronic equipment. This inverter has a hard shell and is not limited to home, commercial, industrial, marine and other scenarios.
Low Frequency Inverter: MPPT Solar Charger (Optional)
Optional solar charger with MPPT functionality, rated output current up to 60A.
Low Frequency Inverter: Pure Sine Wave Output
Provides pure sine wave output, same as input in bypass mode.
Low Frequency Inverter: Multiple Input Voltages
Supports nominal input voltages of 12.0Vdc, 24.0Vdc, and 48.0Vdc.
Low Frequency Inverter: Efficient Operation
Nominal efficiency greater than 88% and line mode efficiency >95%.
Electrical Specifications | ||||||||||||
Model | 1KW | 1.5KW | 2KW | 3KW | 4KW | 5KW | 6KW | 8KW | 10KW | 12KW | ||
Inverter Output | Continuous Output | 1KW | 1.5KW | 2KW | 3KW | 4KW | 5KW | 6KW | 8KW | 10KW | 12KW | |
Power | ||||||||||||
Surge Rating(20ms) | 3KW | 4.5KW | 6KW | 9KW | 12KW | 15KW | 18KW | 24KW | 30KW | 36KW | ||
Output Waveform | Pure Sine wave/Same as input(Bypass Mode) | |||||||||||
Nominal Efficiency | >88%(Peak) | |||||||||||
Line Mode Efficiency | >95% | |||||||||||
Power Factor | 0.9- 1.0 | |||||||||||
Nominal Output Voltage rms | 100- 110- 120Vac / 220-230-240Vac | |||||||||||
Output Voltage | ± 10% RMS | |||||||||||
Regulation | ||||||||||||
Output Frequency | 50Hz ± 0.3Hz/60Hz ± 0.3Hz | |||||||||||
Short Circuit Protection | Yes( 1sec after fault ) | |||||||||||
Typical transfer Time | 10ms(Max) | |||||||||||
THD | < 10% | |||||||||||
DC Input | Nominal Input Voltage | 12.0Vdc / 24.0Vdc / 48.0Vdc | 24.0Vdc /48.0Vdc | 48.0Vdc | ||||||||
Minimum Start Voltage | 10.0Vdc / 10.5Vdc for 12Vdc Mode | *2 for 24Vdc, *4 for 48Vdc; | ||||||||||
Low Battery Alarm | 10.5Vdc / 11.0Vdc for 12Vdc Mode | |||||||||||
Low Battery Trip | 10.0Vdc / 10.5Vdc for 12Vdc Mode | |||||||||||
High Voltage Alarm | 16.0Vdc for 12Vdc Mode | |||||||||||
Low Battery voltage recover | 15.5Vdc for 12Vdc Mode | |||||||||||
Idle Consumption-Search Mode | < 25 W when Power Saver On.(Refer to Table ) | |||||||||||
Charger | Output Voltage | Depends on battery type (Refer to Table 2.5.2) | ||||||||||
Charger Breaker Rating | 10A | 15A | 20A | 20A | 20A | 30A | 30A | 40A | 40A | 40A | ||
Max Charge Power | 1/3 Rating Power (Refer to Table 2.5.3) | |||||||||||
Rate | ||||||||||||
Battery Initial Voltage for Start | 10- 15.7Vdc for 12Vdc Mode | *2 for 24Vdc, *4 for 48Vdc; | ||||||||||
Over Charge Protection S.D. | 15.7Vdc for 12Vdc Mode | |||||||||||
BTS | Battery Temperature Sensor (Optional) | Yes(Refer to the table ) Variances in Charging Voltage & S.D Voltage Base on the Battery Temperature. | ||||||||||
Bypass & Protection | Input Voltage Waveform | Sine wave (Grid or Generator) | ||||||||||
Nominal Voltage | 110Vac | 120Vac | 220Va c | 230Va c | 230Vac | |||||||
Max Input AC Voltage | 150VAC For 120Vac LV Mode;300VAC For 230Vac HV Mode; | |||||||||||
Nominal Input Frequency | 50Hz or 60Hz | |||||||||||
Low Freq Trip | 47±0.3Hz for 50Hz, 57±0.3Hz for 60Hz | |||||||||||
High Freq Trip | 55±0.3Hz for 50Hz, 65±0.3Hz for 60Hz | |||||||||||
Overload protection (SMPS load) | Circuit Breaker | |||||||||||
Output Short circuit protection | Circuit Breaker | |||||||||||
Bypass breaker rating | 10A | 15A | 20A | 30A | 40A | 40A | 50A | 60A | 63A | 80A | ||
Transfer switch rating | 30Amp for UL & TUV | 40Amp for UL | 80Amp for UL | |||||||||
Bypass without battery connected | Yes (Optional) | |||||||||||
Max bypass current | 30Amp | 50Amp | 80Amp | |||||||||
Solar Charger (Optional) | Rated Voltage | 12Vdc / 24Vdc / 48Vdc | ||||||||||
Solar Input Voltage Range | 18- 150Vdc / 36- 150Vdc / 60- 150Vdc | |||||||||||
Rated Charge Current | 40 ~ 60A | |||||||||||
Rated Output Current | 60A | |||||||||||
Self Consumption | < 10mA | |||||||||||
Bulk Charge(Default) | 14.5Vdc for 12Vdc Mode | ( *2 for 24Vdc, *4 for 48Vdc) | ||||||||||
Floating Charge(Default) | 13.5Vdc for 12Vdc Mode | |||||||||||
Equalization Charge(Default) | 14.0Vdc for 12Vdc Mode | |||||||||||
Over Charge Disconnection | 14.8Vdc for 12Vdc Mode | |||||||||||
Over Charge Recovery | 13.6Vdc for 12Vdc Mode | |||||||||||
Over Discharge Disconnection | 10.8Vdc for 12Vdc Mode | |||||||||||
Over Discharge Reconnection | 12.3Vdc for 12Vdc Mode | |||||||||||
Temperature Compensation | 5mV/C/2V | |||||||||||
Ambient Temperature | -25C~60C | |||||||||||
Mechanical Specifications | Mounting | Wall Mount | ||||||||||
Inverter Dimensions(L*W*H) | 340*420*200mm | 420*420*200mm | 558*415*200mm | 618*430*238mm | ||||||||
Inverter Weight(Solar Chg)KG | 16+3 | 29+3 | 22+3 | 26+3 | 31+3 | 35+3 | 37+3 | 60+3 | 64+3 | 74+3 | ||
Shipping Weight(Solar Chg)KG | 19+3 | 22+3 | 25+3 | 29+3 | 36+3 | 39+3 | 41+3 | 70+3 | 74+3 | 84+3 | ||
Display | Status LEDs / Status LEDs+LCD | |||||||||||
Standard Warranty | 2 Years (Optional) |